Lysaght C- Section Verandah & Carport Selection Tables. Attached and Freestanding Systems. Roofing & Walling Solutions. Rainwater Solutions PDF

Title Lysaght C- Section Verandah & Carport Selection Tables. Attached and Freestanding Systems. Roofing & Walling Solutions. Rainwater Solutions
Author Tom Payne
Course Principles Of Engineering Practice
Institution Massachusetts Institute of Technology
Pages 82
File Size 3.4 MB
File Type PDF
Total Downloads 26
Total Views 127

Summary

C section span tables...


Description

LYSAGHT® C-SECTION VERANDAH & CARPORT SELECTION TABLES

Home Improvements

Roofing & Walling Solutions

Rainwater Solutions

Attached and Freestanding Systems Structural Solutions

Fencing Solutions

House Framing Solutions

Customer Support

SPAN TABLES for attached and freestanding verandahs and carports Region A, wind speed classifications W28, W33, W37, W41 metres/second

Adding a carport, verandah or patio to your home these days is not just about having some extra place to park the car or for the kids to keep out of the rain. It's about creating an appealing style, adding value to your home and, more importantly, giving you more space to enjoy your lifestyle. The LYSAGHT ® range of Home Improvement products allows you to add these features with the strength and style of COLORBOND ® steel.

The LYSAGHT ® carport and verandah system is engineered to the highest standards. The tables contained within this booklet are intended to simplify the task of designing a system to suit the various applications.

© Copyright BlueScope Steel Limited, July 2004

PAGE 1

IMPORTANT DISCLAIMER

Date of issue

The information contained in this Product Guide is subject to change. BlueScope Steel Limited (“BlueScope Steel”) does not warrant that the information is correct or complete or is a definitive statement of procedures. BlueScope Steel reserves the right to vary the content of this Product Guide as and when required and in its discretion. You should make independent inquiries to satisfy yourself as to the correctness and currency of the content. You accept all risks and responsibility for losses, damages, costs and other consequences resulting directly or indirectly from using this Product Guide and any information or material available from it. BlueScope Steel, its agents, officers, employees, subcontractors or consultants make no representations, express or implied, as to the accuracy of the information and data contained in this Product Guide; and make no representations, either expressed or implied, as to the suitability of the said information and data for any particular purpose. To the maximum extent permitted by law, BlueScope Steel expressly disclaims all and any liability to any persons whatsoever in respect of anything done or not done, arising directly or indirectly, by any such person in reliance, whether in whole or in part, on this document.

This Product Guide is version 1.1, issued on 20 July 2004.

PAGE 2

BlueScope Steel may make changes to this Product Guide in its sole discretion. It is your responsibility to make sure that you are using the most up-to-date version of the Product Guide.

Purchase terms and conditions Additional terms and conditions apply to the purchase of BlueScope Lysaght goods or services, all of which terms and conditions are made a part of the Product Guide by this reference. You agree to abide by those terms and conditions. You may obtain a copy of the terms and conditions by contacting your BlueScope Steel representative. To the extent permitted by law, BlueScope Steel's obligations in respect of its products and services are governed solely by the agreements pursuant to which they are provided, and nothing in this Product Guide should be construed to alter any of those agreements.

Limitation of Liability To the maximum extent permitted by law, in no event will BlueScope Steel be liable to you for any direct, indirect, consequential, exemplary, incidental or punitive damages, including lost profits, even if BlueScope Steel has been advised of the possibility of such damages.

© Copyright BlueScope Steel Limited, July 2004

CONTENTS

General Comments

5

Components

6

Region A, wind speed classification W28 m/s

7

Region A, wind speed classification W37 m/s

45

Type 1A - Attached W28 m/s

8

Type 1A - Attached W37 m/s

46

Type 2A - Attached W28 m/s

11

Type 2A - Attached W37 m/s

49

Type 3A - Attached W28m/s

14

Type 3A - Attached W37 m/s

51

Type 1F - Freestanding W28 m/s

17

Type 1F - Freestanding W37 m/s

53

Type 2F - Freestanding W28 m/s

20

Type 2F - Freestanding W37 m/s

56

Type 3F - Freestanding W28 m/s

23

Type 3F - Freestanding W37 m/s

58

Region A, wind speed classification W33 m/s

27

Region A, wind speed classification W41 m/s

61

Type 1A - Attached W33 m/s

28

Type 1A - Attached W41 m/s

62

Type 2A - Attached W33 m/s

31

Type 2A - Attached W41 m/s

65

Type 3A - Attached W33 m/s

33

Type 3A - Attached W41 m/s

67

Type 1F - Freestanding W33 m/s

36

Type 1F - Freestanding W41 m/s

69

Type 2F - Freestanding W33 m/s

39

Type 2F - Freestanding W41 m/s

72

Type 3F - Freestanding W33 m/s

42

Type 3F - Freestanding W41 m/s

74

Back Channel Details

77

Connection Details

78

Section Details

79

Fibreglass Sheeting/Fascia Reinforcing Bracket

80

© Copyright BlueScope Steel Limited, July 2004

PAGE 3

PAGE 4

© Copyright BlueScope Steel Limited, July 2004

GENERAL COMMENTS 1.

2.

These tables have been prepared for a range of attached and freestanding verandah and carport designs using structural sections and roof sheeting manufactured by BlueScope LYSAGHT ®. Design information has been taken from; – S.A.A. Loading Code AS/NZS 1170.0 - 2002 – Part 0: General Principles. – S.A.A. Loading Code AS/NZS 1170.1 - 2002 – Part 1: Permanent, imposed and other actions. – S.A.A. Loading Code AS/NZS 1170.2 - 2002 – Part 2: Wind Actions. – S.A.A. Steel Structures Code AS/NZ 4100 – 1998. – S.A.A. Concrete Structures Code AS 3600 – 2001. –

3.

4.

5.

6.

7.

8.

S.A.A. Cold – Formed Steel Structures Code AS/NZ 4600 – 1996. – S.A.A. Design and installation of Metal Roofing Code AS 1562.1. – Wind Loads for Housing, AS 4055-1992. – Using LYSAGHT ® Zeds & Cees for purlins and girts – January 2002. The design of cladding spans and their related connections has been determined by testing in accordance with the following standards; – AS4040.2-1992 Methods of testing sheet roof and wall cladding – Resistance to wind pressures for cyclone regions. – AS1562.1-1992 Design and installation of sheet roof and wall cladding – Metal. The information in this booklet is suitable for use only in areas where a tropical cyclone is unlikely to occur as defined in SAA Loading Code AS/NZS 1170. 2 – 2002 Part 2: Wind Actions. Designs have been classified using a similar system to that outlined in AS 4055 and the BCA. The designs contained within these tables relate to gust wind speeds of W28, W33, W37, W41 m/s to region A in terrain with numerous closely spaced obstructions having the size of domestic houses (3m to 5m high). All erection and connection details to be in accordance with the relevant standard LYSAGHT ® connection detail drawings contained in this document. Footings shall be to the sizes and shape nominated in the span tables and founded into a firm natural soil base. Concrete to have a minimum strength of 20MPa with a maximum 80mm slump. The capacity of the existing structure to withstand the additional loads arising from the attached verandah or carport must be verified by a suitably qualified engineer. It is advised to check with your local government authority to determine any specific requirements for the attachment to existing structures.

© Copyright BlueScope Steel Limited, July 2004

9.

The roof cladding and supporting structure have been designed as ‘No Foot Traffic’ structures. Cladding and structural members shall not be walked on during and after construction. Signs stating ‘No Foot Traffic’ shall be installed to roof cladding at all access points in accordance with local workcover legislation. We recommend the use of two metre minimum length crawl boards for any access to the roof sheeting during construction or the service life of the roof for maintenance or any other access purpose to prevent any damage to the roofing.

10. The span tables have been designed as a complete set. Only the components specified in them may be used. 11. The verandah and carport tables are not sufficient for full enclosure. For one side enclosed tables, a verandah and carport are considered open if at least three of it's four sides are open and at least one third of it's perimeter is open. For a side to be considered open, the roof cladding adjacent to that side must be at least 500mm from another building or allotment boundary. 12. Dead loads have been used where applicable, including self-weight of structure and cladding only. No allowance has been made for ceilings. 13. Minimum roof pitch shall be 1°, 1 in 60, HSKL700 .48 BMT 2°, 1 in 30, Otherwise 14. The Serviceability criteria used for attached and free standing is Span/150. 15. For freestanding verandahs & carports that have 1side enclosed, the enclosed side must have column supports for the wall cladding at 2500mm maximum centres for the full length of the enclosure. The exception to this rule is where the overall total length of the enclosed side is 5000mm in which case only 2 corner columns are required, effectively supporting 2500mm of wind load each. 16. All edge fascia beams are permitted to have only one adjoining rafter beam between columns. Designs requiring more than one rafter beam to the edge fascia beam between columns need to be carried out by a suitably qualified engineer. The LYSAGHT ® carport and verandah system have been designed as a complete unit. Any warranties provided by LYSAGHT ® will only apply if all components have been supplied by LYSAGHT ®, and installed in accordance with LYSAGHT ® details. To ensure maximum lifespan for your LYSAGHT ® verandah or carport, consult your nearest LYSAGHT ® branch for information regarding maintenance, handling, storage and any other technical assistance you may require.

PAGE 5

COMPONENTS

STRUCTURAL MEMBERS SECTION L 55mm

52mm

D

1.2mm

t

45mm

L B

t mm D mm

B mm

L mm

C15012

1.2

152

64

14.5

C15015

1.5

152

64

15.5

C15019

1.9

152

64

16.5

C15024

2.4

152

64

18.5

C20015

1.5

203

76

15.5

C20019

1.9

203

76

19.0

C20024

2.4

203

76

21.0

C25019

1.9

254

76

18.5

C25024

2.4

254

76

20.5

Back channel C Section LYSAGHT KLIP-LOK 700 HI-STRENGTH™

SIDE LAP FASTENER - TYPICAL

Insert rivet on side laps at 1200 crs, KL700HS only.

DECKING PROFILES/FIXINGS Fastener location

Fasteners: 10-16 x 16 Metal TEK screws with EPDM seal at each support. 3.2mm Bulb-tite structural rivets at back channel supports and side laps.

43 mm 700 mm cover

LYSAGHT KLIP-LOK 700 HI-STRENGTH™ Note: Side lap fasteners required at all side laps at 1200mm crs. maximum. fastener not required for internal supports. 45 mm

* 250 mm cover

LYSAGHT FLATDEK®

*

Extra fastener for starting sheet.

Fastener Type: 10 - 16 x 16 metal tek screws with EPDM seal, at each support. 3.2mm Bulb-Tite structural rivets at back channel supports and side laps.

PAGE 6

© Copyright BlueScope Steel Limited, July 2004

SPAN TABLES for attached and freestanding verandahs and carports Region A, wind speed classification W28 metres/second

© Copyright BlueScope Steel Limited, July 2004

PAGE 7

TYPE 1A (attached) REGION A, W28 m/s MAXIMUM ALLOWABLE SPAN (mm) Fascia Beam C15012

C15015

Deck Span B 1500 1800 2100 2400 2700 3000 3300 3600 3800 1500 1800 2100 2400 2700 3000 3300 3600 3800

Column Spacing A 5400 5400 5400 5400 5400 5100 5100 5100 5100 5700 5700 5700 5700 5700 5700 5400 5400 5400

Footing Type

Fascia Beam

1 1 1 1 1 1 2 2 2 1 1 1 1 1 2 2 2 2

C15019

ROOF SHEETING LYSAGHT KLIP-LOK 700 HI-STRENGTH™ 0.42 BMT

Deck Span B 1500 1800 2100 2400 2700 3000 3300 3600 3800 1500 1800 2100 2400 2700 3000 3300 3600 3800

C15024

Column Spacing A 6300 6300 6300 6300 6300 6300 6000 6000 6000 6900 6900 6900 6900 6900 6900 6900 6600 6600

1 1 1 1 2 2 2 2 2 1 1 1 2 2 2 2 2 2

X

eave or wall line

W28 & W33 maximum roof span 3900mm, W37 & W41 maximum roof span 3600mm

Footing Type

fall end fascia beam B

LYSAGHT KLIP-LOK 700 HI-STRENGTH™ 0.48 BMT

W28 & W33 maximum roof span 4200mm, W37 & W41 maximum roof span 3800mm LYSAGHT FLATDEK® 0.42 BMT maximum roof span 4200mm

fascia beam

Detail 3

X

A

Detail 2

PLAN

COLUMN SIZE 50 x 50 x 1.60mm SHS

Detail 1

section 1

3000 max

FOOTING SIZE (mm)

section 6

1. 300 x 300 x 600 deep 2. 450 x 450 x 600 deep 3. 600 x 600 x 700 deep

NOTES 1. Column spacing A is the distance between column centres. Deck Span B is the distance between the back of the back channel and the inside face of the fascia beam.

B OPTION ONE

SECTION X-X

section 2 or 4 section 6

3000 max

2. These tables must be read in conjunction with the General Comments on page 5 and details shown on pages 77 - 80. 3. The end fascia beam is non structural and may be omitted. 4. Interpolation may be used for values required between those shown in the tables.

B OPTION TWO

PAGE 8

SECTION X-X © Copyright BlueScope Steel Limited, July 2004

TYPE 1A (attached) REGION A, W28 m/s MAXIMUM ALLOWABLE SPAN (mm) Fascia Beam

Deck Span B 1500 1800 2100 2400 2700 3000 3300 3600 3800 1500 1800 2100 2400 2700

C20015

C20019

Column Spacing A 6900 6900 6900 6900 6900 6900 6600 6600 6600 7800 7800 7800 7800 7800

Footing Type 1 1 1 2 2 2 2 2 2 1 1 2 2 2

ROOF SHEETING LYSAGHT KLIP-LOK 700 HI-STRENGTH™ 0.42 BMT

Fascia Beam

Deck Span B 3000 3300 3600 3800 1500 1800 2100 2400 2700 3000 3300 3600 3800

C20024

Column Spacing A 7500 7500 7200 7200 8400 8400 8400 8400 8400 8100 8100 7800 7800

2 2 2 3 1 1 2 2 2 2 2 3 3

X

eave or wall line

W28 & W33 maximum roof span 3900mm, W37 & W41 maximum roof span 3600mm

Footing Type

fall end fascia beam B

LYSAGHT KLIP-LOK 700 HI-STRENGTH™ 0.48 BMT

W28 & W33 maximum roof span 4200mm, W37 & W41 maximum roof span 3800mm LYSAGHT FLATDEK® 0.42 BMT maximum roof span 4200mm

Detail 1

fascia beam

Detail 3

X

A

Detail 2

PLAN 50 x 50 x 1.60mm SHS

section 1

section 6

3000 max

COLUMN SIZE

FOOTING SIZE (mm) 1. 300 x 300 x 600 deep 2. 450 x 450 x 600 deep 3. 600 x 600 x 700 deep B

NOTES 1. Column spacing A is the distance between column centres. Deck Span B is the distance between the back of the back channel and the inside face of the fascia beam.

OPTION ONE

SECTION X-X

section 2 or 4 section 6

3000 max

2. These tables must be read in conjunction with the General Comments on page 5 and details shown on pages 77 - 80. 3. The end fascia beam is non structural and may be omitted. 4. Interpolation may be used for values required between those shown in the tables.

B OPTION TWO

© Copyright BlueScope Steel Limited, July 2004

SECTION X-X

PAGE 9

TYPE 1A (attached) REGION A, W28 m/s MAXIMUM ALLOWABLE SPAN (mm) Fascia Beam C25019

Deck Span B 1500 1800 2100 2400 2700 3000 3300 3600 3800

Column Spacing A 8100 8100 8100 8100 8100 8100 8100 7800 7800

Footing Type

Fascia Beam

1 1 2 2 2 2 2 3 3

C25024

Deck Span B 1500 1800 2100 2400 2700 3000 3300 3600 3800

Column Spacing A 9000 9000 9000 9000 9000 9000 8700 8700 8400

Footing Type 1 2 2 2 2 2 3 3 3

ROOF SHEETING LYSAGHT KLIP-LOK 700 HI-STRENGTH™ 0.42 BMT

X

eave or wall line

W28 & W33 maximum roof span 3900mm, W37 & W41 maximum roof span 3600mm

fall end fascia beam

LYSAGHT KLIP-LOK 700 HI-STRENGTH™ 0.48 BMT

B

W28 & W33 maximum roof span 4200mm, W37 & W41 maximum roof span 3800mm LYSAGHT FLATDEK® 0.42 BMT maximum roof span 4200mm

fascia beam

Detail 3

X

A

section 1

1. 300 x 300 x 600 deep 2. 450 x 450 x 600 deep 3. 600 x 600 x 700 deep

NOTES

B OPTION ONE

SECTION X-X

section 2 or 4 section 6

3000 max

2. These tables must be read in conjunction with the General Comments on page 5 and details shown on pages 77 - 80. 3. The end fascia beam is non structural and may be omitted. 4. Interpolation may be used for values required between those shown in the tables.

B OPTION TWO

PAGE 10

section 6

3000 max

FOOTING SIZE (mm)

1. Column spacing A is the distance between column centres. Deck Span B is the distance between the back of the back channel and the inside face of the fascia beam.

Detail 2

PLAN

COLUMN SIZE 50 x 50 x 1.60mm SHS

Detail 1

SECTION X-X

© Copyright BlueScope Steel Limited, July 2004

TYPE 2A (attached) REGION A, W28 m/s MAXIMUM ALLOWABLE SPAN (mm) Beam 1

Beam 2

C15012

C15012

C15015

C15015

Beam Span B 3600 3900 4200 4500 4800 5100 5400 3600 3900 4200 4500 4800 5100

Beam Spacing S 3800 3800 3600 3000 2400 1900 1500 3800 3800 3800 3800 3100 2500

Column Spacing A 5700 5100 4800 5400 4500 3500 2700 6600 6300 6000 6000 6200 5000

Footing Type 1 1 1 1 1 1 1 1 1 1 2 2 1

Beam 1

Beam 2

C15019

C15019

Beam Span B 5400 5700

Beam Spacing S 2100 1700

Column Spacing A 4200 3400

Footing Type

3...