OTIS
FIELD COMPONENT MANUAL
European and Transcontinental Operations
Part
: 4 - AA 3
No.
: GCA 21240 D VIIIa
Vintage : 01 / 8 Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 1 / 25
Date
: 27-Jun-1995
MCS - LCB_II List of Installation Parameters
Authorization Date D1: 27-Jun-1995 Running on PCB:
GCA 21240 D1 - D3 GDA 21240 D1 - D3
Software Version:
GAA 30082 BAC
Document Revision: - Original Document - OTIS 2000 features add. - Triplex parameter added - Secure Access revised - BSM mode added - MCS220M, LSVF-W, ELD, REM III added 06 - Jun - 95 GAA 30082 BAB A. Gerwing - not distributed 27 - Jun - 95 GAA 30082 BAC A.Gerwing - CPC-TYP, N+2, ELD-MSG, ELD-DOOR 24 - May - 93 03 - Dec - 93 29 - Apr - 94 02 - Jun - 94 16 - Jun - 94 17 - Jan - 95
GAA 30082 AAA GAA 30082 AAB GAA 30082 AAC GAA 30082 AAD GAA 30082 AAE GAA 30082 BAA
J. Schulte A.Gerwing M. Hnida M. Hnida J. Schulte J. Schulte
Copyright 1995, OTIS GmbH Berlin No part of this document may be copied or reproduced in any form or by any means without the prior written consent of OTIS GmbH.
FIELD COMPONENT MANUAL
EuropeanOTIS and Transcontinental
Part
: 4 - AA 3
No.
: GCA 21240 D VIIIa
Vintage : 01 / 8
Operations
Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 2 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
System: No.
Symbol
Default
0
TOP
2
Top position: 1 (1) 31
1
LOBBY
0
Lobby position: 0 (1) 31
2
BOTTOM
0
Bottom position: 0 (1) 30
3
CFT-P
255
Cafeteria Position: 0 (1) 31 > 31 Disabled
4
OPERAT
1
Operation FCL/DCL/SAPB: 0 FCL 1 DCL 2 SAPB
5
EN-BSM
0
Enable BSM mode (for DCL: both Up- and Down Hall Calls at lobby): 0 Disabled 1 Enabled
6
CONFIG
0
General configuration: 0 ETO 1 NAO
7
PI
4
Type of serial Position Indicator: 0 7/16 Segment 1 Multil. 2 Australian Dot Matrix 3 Australian Dot Matrix with CUDL/CDDL 4 OTIS 2000: LCD and ELD
8
ELD-fOPG
20
front door movement time: opening 0 (0.1) 10.0 s 0 = automatic (not yet implem.)
9
ELD-fCLG
20
front door movement time: closing 0 (0.1) 10.0 s 0 = automatic (not yet implem.)
10
ELD-rOPG
20
rear door movement time: opening 0 (0.1) 10.0 s 0 = automatic (not yet implem.)
Purpose and Range
FIELD COMPONENT MANUAL
EuropeanOTIS and Transcontinental
: 4 - AA 3
No.
: GCA 21240 D VIIIa
Vintage : 01 / 8
Operations
Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 3 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
System (continued):
R) R) R) R) R) R) R) R)
Part
No.
Symbol
Default
11
ELD-rCLG
20
rear door movement time: closing 0 (0.1) 10.0 s 0 = automatic (not yet implem.)
12
ELD-LNG
5
set Language for ELD: 0 (1) 19 0 SwiGer, 1 SwiFRA, 5 UK, 6 Spain, 10 Sweden, 11 Luxem, 15 Denmar, 16 SthAfr,
Purpose and Range
2 7 12 17
SwiIta, Nether, Belg, Finlnd,
3 8 13 18
Fra, Ger, Por, Ara,
4 9 14 19
Italy, Aus, Egy, Kuw
13
ELD-Sym1
0
Enable Non-Smoking symbol: 0 Disabled 1 symbol is displayed
14
ELD-DOOR
0
select type of door display: 0: 1 COP for 1 door or 2 COPs for 2 doors 1: only 1 COP for 2 doors
15
ELD-MSG
0
enables customer messages: 0: no customer messages are displayed by ELD 1: customer messages are enabled (use SETUP-ELD to define the texts)
16
EN-SFR
0
Enable SFR (signal flicker): 0 Disabled 1 Enabled
17
LR-T
20
18
EN-HLC
0
Enable Hall Lanterns on car calls: 0 Disabled 1 HLC 2 HL also during closing 3 HLC and during door closing
19
HDL-TY
0
Hall Direction Lantern Type of OTIS 2000 Hall Button Box: 0 Direction Indicator 1 Hall Lantern
20
HL-SET
0
Hall Lantern/Gong Setup: 0 HL/G at same pins 1 HL/G at 1 2/3 4 2 HL/G at 3 4/1 2
FAN (LR) time: 0 (1) 255 s
FIELD COMPONENT MANUAL
EuropeanOTIS and Transcontinental
Part
: 4 - AA 3
No.
: GCA 21240 D VIIIa
Vintage : 01 / 8
Operations
Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 4 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
System (continued): No.
Symbol
Default
21
CR-DIR
0
Correction Fast Run Preferred Direction: 0 Down 1 Up
22
EN-RR
0
Enable Reduced Run (RR): 0 Disabled 1 Enabled (short or medium run)
23
DZCNT
1
Use DZ for SL counting (for Short Run): 0 Disabled 1 Enabled
24
EN-DZI
0
Enable DZI (Door Zone Indicator): 0 Disabled 1 Enabled (only if no Door ByPass)
25
ERO-TYP
0
Define ERO type 0 without limit 1 with limit at terminal landings (same as TCI-limit) 2 ERO-input disabled (for LCB_II version D2)
26
C-CHK
0
Enable C-Circuit Check: 0 Disabled 1 Enabled
27
MD/AES
0
select use of MD input (P7:9, only MCS220M): 0 not connected 1 MD: DCS-input for Multi Door (manual plus autom. landing doors) 2 AES: ES-input if RSS or ESB is used
28
CPC-TYP
0
select use of CPC outputs: 0 car position contact 1 ’car here’ light 2 french SSM
29
N+2 WIRE
0
enable 3 wire buttons: 0 normal car and hall buttons 1 3 wire car buttons 1 3 wire hall buttons 1 3 wire car and hall buttons
R) R)
R) R) R) R) R) R) R) R) R) R) R)
Purpose and Range
FIELD COMPONENT MANUAL
EuropeanOTIS and Transcontinental
Part
: 4 - AA 3
No.
: GCA 21240 D VIIIa
Vintage : 01 / 8
Operations
Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 5 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
OCSS: No.
Symbol
Default
0
CPR-T
20
Car Call Preference: 0 (0.1) 25.5 s
1
ARD-P
255
Automatic Return Device Position: 0 (1) 31 > 31 Disabled
2
ARD-T
0
Set Delay for ARD (Automayic Return Device) mode: 0 (10) 2550 s
3
L-PARK
0
Lobby Park Option: 0 Disabled 1 Enabled
4
CTL/PKS
0
Select CTL or PKS switch: 0 CTL switch is connected 1 PKS switch is connected
5
PKS-P
255
6
PKS-TY
0
Parking Shutoff Type: 0 ETO 1 NAO 2 ETO with door open after shutdown
7
PKS-T
0
Parking Shutoff Time: 0 (1) 255 s
8
PKS-DO
0
PKS default door: 0 Both doors will open at PKS-P 1 Only front door opens 2 Only rear door opens
9
EN-SHB
0
Enable Separate Hall Buttons: 0 Normal HB-operation 1 Rear HB as Separate Riser
10
DCP-T
50
Time until DCP-mode (delayed car protection): 25 (1) 255 s
11
CTL-DO
0
CTL default door (car to any landing): 0 Both doors will open at CTL-P 1 Only front door opens 2 Only rear door opens
Purpose and Range
Parking Service Position: 0 (1) 31 > 31 Disabled
FIELD COMPONENT MANUAL
EuropeanOTIS and Transcontinental
Part
: 4 - AA 3
No.
: GCA 21240 D VIIIa
Vintage : 01 / 8
Operations
Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 6 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
OCSS (continued): No.
Symbol
Default
12
CTL-P
255
13
ANS
0
ANS (anti nuisance service): 0 Disabled >0 Number of calls to trigger ANS
14
ATT
0
ATT (Attendant Service) type: 0 Start with DCB or RDCB 1 Start with ATTU or ATTD 2 NAO (USA)
15
ISC
0
Independent Service: 0 Start on CCB 1 Start on DCB 2 Start on ISD/ISU 3 NAO (USA)
16
CTL-TY
0
Select Car To Landing Type: 0 ETO 1 NAO
17
SPEECH
0
Speech Mode: 0 Floor message on CC only 1 Floor message also on HC
18
DOC
0
Door Reopen Count: 0 No limit 1 (1) 255 Number of allowed door reopenings
19
DS-CCB
0
Disable CCs behind moving car: 0 CCs behind allowed 1 CCs behind not allowed
20
DS-DOB
0
Disable DOB button: 0 DOB/RDOB always enabled 1 DOB disabled if door closed 2 RDOB disabled if door closed 3 Both disabled if door closed
Purpose and Range CTL (Car To Any Landing) position: 0 (1) 31 > 31 Disabled
FIELD COMPONENT MANUAL
EuropeanOTIS and Transcontinental
Part
: 4 - AA 3
No.
: GCA 21240 D VIIIa
Vintage : 01 / 8
Operations
Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 7 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Group: No.
Symbol
Default
0
GRP-NO
1
Car identifier in group: 1 (1) 3
1
GROUP
1
Number of cars in group: 1 (1) 3
2
CNL
1
Cars parking in Lobby: 1 (1) 3
3
MIT-ST
0
MIT (Moderate incomming traffic) Startdelay: 0 (1) 255 s
4
MIT-T
0
MIT Time-Out: 0 (1) 255 s
5
MIT-VD
0
MIT Variable Interval Dispatch: 0 (1) 255 s
6
DUPK-P
255
Dual Up Peak Border Position: 0 (1) 31 > 31 Disabled
7
DUPK-G
0
Dual Up Peak Group: 0 Car belongs to subgroup 1 1 Car belongs to subgroup 2
8
MOT-T
0
MOT (Moderate Outgoing traffic) Time-Out: 0 (1) 255 s
9
EN-UCB
0
Enable Up Call Bypass: 0 Disabled 1 Enabled
10
TFS-P
255
Transfer Floor Position: 0 (1) 31 > 31 Disabled
11
PARK-1
255
Park Clock Position 1: 0 (1) 31 > 31 Disabled
12
PARK-2
255
Park Clock Position 2: 0 (1) 31 > 31 Disabled
Purpose and Range
FIELD COMPONENT MANUAL
EuropeanOTIS and Transcontinental
Part
: 4 - AA 3
No.
: GCA 21240 D VIIIa
Vintage : 01 / 8
Operations
Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 8 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Group (continued): No.
Symbol
Default
13
PARK-3
255
Park Clock Position 3: 0 (1) 31 > 31 Disabled
14
PARK-4
255
Park Clock Position 4: 0 (1) 31 > 31 Disabled
15
PARK-5
255
Park Clock Position 5: 0 (1) 31 > 31 Disabled
16
PARK-6
255
Park Clock Position 6: 0 (1) 31 > 31 Disabled
17
PARK-7
255
Park Clock Position 7: 0 (1) 31 > 31 Disabled
18
PARK-8
255
Park Clock Position 8: 0 (1) 31 > 31 Disabled
19
EN-ZBS
0
Purpose and Range
Enable separate basement zone: 0 No free car parks in basement zone 1 A free car parks in basement zone
FIELD COMPONENT MANUAL
EuropeanOTIS and Transcontinental
: 4 - AA 3
No.
: GCA 21240 D VIIIa
Vintage : 01 / 8
Operations
Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 9 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Drive: No.
Symbol
Default
0
DRIVE
1
1
Part
C-TYPE
2
Purpose and Range Drive Type: 0 1-SP 1 2-SP, G-L 2 G-S/D 3 G-L with SL 4 G-L with SL 5 2-SP, G-L 6 G-S/D 7 SPEC60 8 G-D NAO 9 G-D NAO 10 MOT-VLV 11 SOL-VLV 12 MOT-VLV 13 SOL-VLV 14 LSVF 15 LSVF 16 LSVF-W 17 LSVF-W
XADO XADO XADO ADO ADO ADO XADO ADO ADO ADO XADO XADO ADO XADO ADO XADO
Controller Type: 0 MCS 310 1 MCS 310 CA, HY 2 MCS 120, MCS 220 3 MCS 220 M
2
1AT
5
1A Time: 0 (0.1) 25.5 s
3
2AT
5
2A Time: 0 (0.1) 25.5 s
4
DDP
32
DDP Time (fast run): 0 (1) 45 s
5
3P
32
3P Time (slow run): 0 (1) 45 s
6
SPEED
100
Speed (fast run mode): 25 40 63 100 160 175 250 cm/s
(Europa 2000) (Cargo 2000) (OTIS 2000) (OTIS 2000)
FIELD COMPONENT MANUAL
EuropeanOTIS and Transcontinental
Part
: 4 - AA 3
No.
: GCA 21240 D VIIIa
Vintage : 01 / 8
Operations
Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 10 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Drive (continued): No.
Symbol
Default
7
EN-MPD
0
Enable Motor Protection Device: 0 Disabled 1 Enabled
8
MPD-T
10
Motor Protection Device Time: 0 (1) 254 s 255 wait forever
9
HY-TYP
0
Hydro Drive Type for Hydro: 0 Star - Delta 1 Soft 2 Direct
10
L-T
10
Set Star/Soft Time for Hydro: 0 (0.1) 25.5 s
11
UX-D
20
Set Star/Delta gap / add. Soft Time (L+UX) for Hydro: 0.06 (0.004) 0.2 s
12
UXT-D
0
Set delay between UX and UXT for Hydro: (contract option) 0 (0.1) 1 s
13
EN-PLS
1
Enable PLS1 (Oil-Max-Pressure Limit Switch) for Hydro: 0 Disabled 1 Enabled
14
EN-OTS
1
Enable OTS (Oil-Over Temperature Switch) for Hydro: 0 Disabled 1 Enabled
15
ACD/UXT
0
Select ACD (Anti Creeping Device) or UXT output for Hydro: 0 ACD and UXT disabled 1 ACD enabled 2 UXT enabled (contract option)
16
P-OFF-D
0
Set Power Off delay for LSVF-W 0, 255 Disabled 1 (1) 254 s
17
P-ON-D
10
Set Power On delay for LSVF-W 8 (1) 20 s
Purpose and Range
FIELD COMPONENT MANUAL
EuropeanOTIS and Transcontinental
Part
: 4 - AA 3
No.
: GCA 21240 D VIIIa
Vintage : 01 / 8
Operations
Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 11 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Drive (continued): No.
Symbol
Default
18
EN-J
1
Enable 3-Phase Detection (J-Relay) 0 Disabled 1 Enabled
19
J-T
1
Number of periods necessary to detect a fault 0 (1) 4
20
EN-BCD
1
Enable Brake Current Detection: 0 Disabled 1 Enabled
21
BON-D
10
Delay of BCD (after lifted brake) 0 (0.1) 10 s
22
BFLT-T
15
Max. fault time of BCD 0 (0.1) 10 s
23
BOFF-D
15
Delay of BCD (after fallen brake) 0 (0.1) 10 s
Purpose and Range
FIELD COMPONENT MANUAL
EuropeanOTIS and Transcontinental
: 4 - AA 3
No.
: GCA 21240 D VIIIa
Vintage : 01 / 8
Operations
Software Data
PRODUCT ADMINISTRATION
MCS - LCB_II List of Installation Parameters
Page
: 12 / 25
Date
: 27-Jun-1995
Version: GAA 30082 BAC
Doors: No.
Symbol
Default
0
DOOR
2
1
Part
REAR
2