D

R

E

PHOTOCELL

COMMISSIONING AND TEST PROCEDURE 1- Take the car to the landing level. Connect 220V AC to power supply input (5-7 terminals) of board. Do not forget to connect earth connection (terminal 6). 2- Set 4 dip-switches on the board according to door specifications. 3- Switch ON supply and see OK led is flashing. 4- To start learninig procedure push program button (51). If door is open, door will close slowly and will open if door is close door will open slowly and will close. This process must be completed succesfully. Otherwise system never works properly. 5- After completing Learninig process, push TEST button (50) shortly and test door's operations. Operational setting will be the same as normal operation. 6- After completing Test process succesfully, connect door command inputs coming from lift control panel to input terminals (8-CLOSE, 10-COMMON, 12-OPEN). Inputs voltage must be 12V-220V AC/DC. Test door by activating door open and close commands from controller.

D

FOR MORE INFO, PLEASE READ FERMATOR VVVF-4+ USER MANUAL

DOOR OPEN SIGNAL INPUTS

C

GREEN

White Black Black White

17 18 19 20

SLOW CLOSE RE-OPEN FLOOR LEVEL

COMMON OPEN

230V AC

EARTH / PE

NEUTRAL / N-Mp

+

CLOSE SPEED

AUTOADJUSTMENT (PROGRAM)

53

51

8 CLOSE 9 +12V 10 COMMON 11 0V 12 OPEN 7

F

6

GND

5

N

C

....OK!

-

+

OBSTRUCTION

40

OPEN SPEED

39 38 37

PHOTOCELL

DIP-SWITCH

ON

-

+

SAFETY

54

36 35

OFF 1

CLOSED

2 3 4

34 33 32

DIP-SWITCH SETTINGS OFF

SUPPLY

PHASE / L1-R

-

STATUS

ON

OPENED

B

31

1 : ON Single Input Signal (8-10) OFF Double Input Signal (8-10-12)

INPUTS

CLOSE

SIGNAL INPUTS

PRIORITY INPUTS

+12V COM

25 21 26

50

41

RECEIVER

23

52

TEST BUTTON

EMITTER

POWER SWITCH

B

TEST

PHOTOCELL FOTOSEL

YELLOW

V+ TX RX V-

SERIAL PORT

13 14 15 16

30

2 : ON Automatic Landing Door OFF Manual Landing Door

55

3 : ON Left&Central Opening OFF Right Opening 4 : ON Automatic Self Control (MASTER) OFF Manual Control (SLAVE)

ENCODER ENKODER

56

VVVF-4+

MOTOR

Fermator

M

A

A

Title Size

FERMATOR VVVF-4+ DOOR BOARD CONNECTION DIAGRAM Number

A3 Date: File:

16-Apr-2014 Sheet of E:\PROJELER\PROTEL\OZEL\OZEL.ddb Drawn By:

Revision...