Group 3 rpt Air Particle PDF

Title Group 3 rpt Air Particle
Author Hussein Muhammad
Course laboratory environment
Institution Universiti Teknologi MARA
Pages 7
File Size 396.9 KB
File Type PDF
Total Downloads 332
Total Views 475

Summary

CAWANGAN PULAU PINANGCEWWATER QUALITY & ENVIRONMENTAL LABORATORYSEMESTER:OCTOBER 2020 – FEBRUARY 2021TITLE OF EXPERIMENT : Air Paricles MeasurementDATE OF EXPERIMENT : 2/11/GROUP : PEC2217KGROUP MEMBERSLECTURER :LEVEL OF OPENNESS : 1DATE OF SUBMISSION : 19/11/ResultsLocation: Outdoor Time (m...


Description

CAWANGAN PULAU PINANG CEW545 WATER QUALITY & ENVIRONMENTAL LABORATORY SEMESTER: OCTOBER 2020 – FEBRUARY 2021 TITLE OF EXPERIMENT : Air Particles Measurement

DATE OF EXPERIMENT : 2/11/2020

GROUP

: PEC2217K1

GROUP MEMBERS

LECTURER

:

LEVEL OF OPENNESS

:1

DATE OF SUBMISSION : 19/11/2020

Results Location: Outdoor Time (min) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Average

Location: Indoor Time (min) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Average

Total particles PM10 PM2.5 (μg/m3) (μg/m3) (μg/m3) 76.6 40.0 18.19 65.3 40.4 16.74 69.2 40.8 16.19 70.9 39.4 15.91 66.4 40.4 14.86 66.7 41.9 15.50 59.2 38.7 14.49 80.0 37.2 14.07 51.0 34.3 13.45 78.3 41.1 12.59 55.5 30.6 12.83 63.4 32.6 12.68 58.8 36.2 12.83 66.8 36.3 12.69 73.0 36.6 12.95 66.7 37.8 14.40 Figures 2: Tables of outdoor air particles

PM1 (μg/m3) 9.47 8.79 8.35 8.29 8.09 7.93 7.45 7.45 7.04 6.96 6.68 6.72 6.77 6.69 6.69 7.56

Total particles PM10 PM2.5 (μg/m3) (μg/m3) (μg/m3) 29.1 17.3 8.69 31.7 18.5 8.50 39.2 19.9 8.71 28.3 18.3 8.27 24.8 16.8 7.51 26.8 14.2 6.93 23.0 14.2 6.85 26.9 14.5 6.38 17.5 12.3 6.43 15.4 9.7 6.11 17.3 9.8 6.26 18.8 10.1 5.78 20.5 10.8 5.82 12.7 8.2 5.52 35.1 10.6 5.41 24.5 13.7 6.88 Figure 3: Tables of indoor air particles

PM1 (μg/m3) 4.57 4.37 4.60 4.30 3.96 3.81 3.73 3.53 3.55 3.34 3.22 3.21 3.14 3.06 2.91 3.69

Discussion These days air quality is quite important to our healthy life. The purpose of this report is to differentiate particulate concentrations for location at indoor and outdoor. For this experiment, our lecturer has provided a sample data result of air particles reading for 15 minutes with the interval of 1 minute. We are also provided with a video on how to use the DustMate Air Monitor as our instrument to measure the air particles. Furthermore, the result data is a reading of indoor and outdoor air particles. The average total particles value of indoor air is 24.5 µg/m3 , lower than the average total particles of outdoor air value which is 66.7 µg/m3 . The values are differed by 42.2 µg/m3 . In addition, all the indoor value of PM10, PM2.5 and PM1 are also lower than the outdoor value. Moreover, based on New Malaysia Ambient Air Quality Standard provided by Department of Environment (DOE) Malaysia, the PM10 particles of outdoor and indoor air which are 37.8 µg/m3 and 13.7 µg/m3 respectively is lower than 100 µg/m3 for 24-hour averaging time. As well as PM2.5 particles, 14.40 µg/m3 for outdoor and 6.88 µg/m3 for indoor air is also lower than 35 µg/m3 for 24- hour averaging time also. Therefore, both the outdoor and indoor air of the data is considered acceptable by DOE Malaysia. There are three basic strategies that have been determined, such as source removal, dilution, and air-cleaning. In each of these classifications, methods can be selected that will reduce exposure. The appropriate strategies to be used, either separately or in combination, must be selected with respect to other and interacting factors. The control variables identified are spatial requirements, lighting factors, thermal factors, air quality, and acoustic factors. Air-cleaning equipment for residential and commercial applications is generally limited to particle filtration. Some gas and vapour removal equipment are available, primarily for commercial applications.

Conclusion To conclude, we have watched the video on the YouTube link provided by the lecture and learn how to use air particle monitor. We have also analyzed the given sample data thoroughly and made some discussion. We have also compared the air particles concentration at outdoor and indoor. Therefore, the objective of the experiment was achieved successfully. Air particles measurement by using Turnkey Instruments Dustmate is one of the options regarding to indicates the air particles measurement. It shows the value of particles compacted in a certain area based on its exposure to the surrounding. The test is basically crucial to determine the air quality in order to sustaining a healthy environment throughout the world. Lastly, we can conclude that the experiment has been done successfully and it is shown trough the result that we have analyse.

References 1. https://www.epa.vic.gov.au/for-community/environmental-information/airquality/pm10particles-in-the-air 2. https://www.airnow.gov/faqs/what-particle-pollution/

Appendices

-

Beroalene Uitm PP, Hus,n Uitm Pp, +60 12-700 4756, You Group La b Envi •• Beroalene Uitm PP

Mcm mana kita buat video ni nnti Husin Uitm Pp

I

Beroalene Uitm PP

Mcm mana kita buat video ni nnti

sorang kena buat 3 steps ikut procedure ,, ,26 PM contoh saya buat step 1-3 ,, 26PM

Beroalene Uitm PP

Ohh jadi a pparatus kita tu nnti mcm mana la 11 ,26 PM Husin Uitm Pp

awak buat step 4-6 ,1 PM tu ambil kat dapur je haha, , .26 PM yang sama bentuk 11,27PM

Beroalene Uitm PP

Kita demo ja la step tu?? 11 27 PM ,,

l;;I

nl

:: ♦

7

'7

/!""',.

'-ii

V

T

.•

.;-

L

,.

\.:-1

A

:,o:i

JI,

ENG

7 43 PM 15/11/2020 "...


Similar Free PDFs