Title | Kettle reboiler Calculation |
---|---|
Author | Fajar Putra |
File Size | 53.8 KB |
File Type | XLSX |
Total Downloads | 277 |
Total Views | 840 |
Download Kettle reboiler Calculation PDF
13 GASOIL REMOVAL REBOILER Fungsi : Tipe : Kettle Reboiler Required Data for Hot Stream (Steam Jenuh ) : P steam = 785.30 psia λ = 688.9 Btu/lb (Table 7 Kern hal 816) T = 518 F SG = 0.028 Required Data Cold Stream : t1 (in) = 141.6 C = 286.88 F t2 (out) = 170 C = 338 F T.av = 155.8 C = 312.44 F Sifat Fisik saat Tav : Cp = 0.513 Btu/lb.F Btu/lb 0.0381 μ = 3.51 Cp rho = 53.12 lb/ft3 k = 0.073 Btu/hr.ft.F M = 49860.00 lb/jam ----> 22616.097 kg/jam Fouling fact. (rd) = 0.001 hr.ft.F/Btu 10 psi Memanaskan aliran bottom product kolom distilasi Allowable ΔP = Steam T1 = 518o F Steam T2 = 518 o F To Reboiler (m1) t1 = 286.88o F Bottom (m2) t2 = 338 o F to column (m3) t3 = 338 o F...