Durga Switchgears – EA 2616 A Grade Electrical Contractors, Page 1a Consultants & Testing Engineers Client: M/S TVS MOTOR COMPANY LIMITED Byathahalli Village, Mysore – 571 311 TEST REPORT FOR OVER CURRENT & EARTH FAULT RELAY Date of Test : 26TH DEC 2013 Location : SUB STATION - I Feeder Name...
Durga Switchgears – EA 2616 A Grade Electrical Contractors, Consultants & Testing Engineers Page 1a Client: M/S TVS MOTOR COMPANY LIMITED Byathahalli Village, Mysore – 571 311 TEST REPORT FOR OVER CURRENT & EARTH FAULT RELAY Date of Test : 26TH DEC 2013 Location : SUB STATION - I Feeder Name :Outgoing Transformer – 4 (1500 KVA) Relay Make : GEC ALSTOM Type / Sl. No. : CDG 31 / 130340150239004 CT Sec. : 5 Amps System Voltage : 11KV CT RATIO: 100/5 – RELAY OVER CURRENT SET AT 75%. i.e., RELAY WILL PICK-UP AT MORE THAN 75 AMPS REASON: - TRANSFORMER HT FULL LOAD CURRENT IS 78 AMPS. SETTINGS:- DESCRIPTION Plug Setting in % Plug Setting in Amps Time Lever DMT OVERCURRENT 75 3.75 0.5 3 EARTH FAULT 10 0.5 0.3 3 SECONDARY INJECTION TEST: % of current Applied current in Amps Graph Time in seconds Actual time in seconds E/F Current in Amps Graph time in seconds Actual Time in seconds R- Phase Y- Phase B- Phase 200 % 7.50 5.00 4.74 --- 4.75 1.00 3.00 2.64 500 % 18.75 2.15 2.20 ---- 2.23 2.50 1.29 1.39 1000% 37.5 1.50 1.48 ---- 1.52 5.00 0.90 0.88 Description R - Phase Earth Fault B - Phase Pick-up Current in Amps 3.98 0.49 3.85 Closing time in seconds 39.41 44.2 55.2 Remarks: - Test results are satisfactory. PRECOMMISSIONING – RELAY TESTING – HIPOT TEST – TRANSFORMER OIL FILTRATION- TRANSFORER/HT/LT BREAKER REPAIRING NO. 8/5, JOHN VASU STREET, MADHAVARAM MILK COLONY, CHENNAI – 600 051. Durga Switchgears – EA 2616 A Grade Electrical Contractors, Consultants & Testing Engineers Page 1b Client: M/S TVS MOTOR COMPANY LIMITED Byathahalli Village, Mysore – 571 311 TEST REPORT FOR INSTANTANEOUS EARTH FAULT RELAY Date of Test : 26TH DEC 2013 Location : SUB STATION - I Feeder Name :Outgoing Transformer – 4 (1500 KVA) Relay Make : GEC ALSTOM Type / Sl. No. : CAG 14 / 13003499944002 CT Sec : 5 Amps System Voltage : 11KV SETTINGS:- PLUG SETTING : 0.5 Amps SECONDARY INJECTION TEST: PLUG SETTING CURRENT APPLIED OPERATION 0.5 0.48 OK 0.75 0.73 OK 1.0 0.99 OK 1.25 1.23 OK 1.5 1.51 OK 1.75 1.76 OK 2.0 1.99 OK Remarks: - Test results are satisfactory. PRECOMMISSIONING – RELAY TESTING – HIPOT TEST – TRANSFORMER OIL FILTRATION- TRANSFORER/HT/LT BREAKER REPAIRING NO. 8/5, JOHN VASU STREET, MADHAVARAM MILK COLONY, CHENNAI – 600 051....