Analysis Visit Report Date Kamis - 04 April 2013 PT Nobel Packaging Indonesia Company PT Multi Fertigung Solution JAKARTA Page 1 REKOMENDASI SYARAT-SYARAT MUTU STANDARD PT MULTI FERTIGUNG SOLUTION COOLING TOWER WATER TREATMENT & CLOSED LOOP WATER TREATMENT Cooling Tower Adalah salah satu media p...


Description

Analysis Visit Report PT Nobel Packaging Indonesia JAKARTA Date Kamis - 04 April 2013 Company PT Multi Fertigung Solution Page 1 REKOMENDASI SYARAT-SYARAT MUTU STANDARD PT MULTI FERTIGUNG SOLUTION COOLING TOWER WATER TREATMENT & CLOSED LOOP WATER TREATMENT Cooling Tower Adalah salah satu media pendingin yang sangat penting dalam operasional sebuah pabrik. Compressor, chiller, heat exchanger dan barometric condenser adalah sebagian dari alat yang menggunakan media pendingin cooling water dalam operasinya. Pengendalian kualitas cooling water akan berpengaruh langsung terhadap kinerja dari alat-alat yang menggunakannya, termasuk pipa distribusi yang mengalirkan cooling water dari cooling tower ke pengguna. Masalah-masalah seperti lifetime alat yang pendek karena korosi, efisiensi pertukaran panas yang rendah akibat akumulasi produk korosi, kerak atau slime (Lumpur), dan naikknya konsumsi energi listrik untuk memompakan cooling water karena adanya penyumbatan pada perpipaan dan alat adalah sebagai akibat dari rendahnya kualitas cooling water. COOLING SYSTEM PROBLEM & CONTROL Masalah-masalah yang umum dijumpai pada pengoperasian suatu unit system pendingin adalah : a) Pengerakan (Scaling) - Menurunkan siklus konsentrasi air yang bersirkulasi - Acid fedd - Deposit control agent b) Pengendapan (Fouling) - Filtration - Dispersi c) Korosi (Corrosion) - Passivation - Precipitation - adsorption d) Pertumbuhan Mikroorganisma (Microorganism Factor) - Oxidizing biocides - Non-oxidizing biocides Parameter-Parameter Dalam Analisa Cooling Water TABEL : SYARAT MUTU AIR DALAM COOLING TOWER & CLOSED SYSTEM. No TEST Satuan Dalam AIR LIMIT COOLING TOWER LIMIT CLOSED LOOP 1 pH VALUE 7,5 - 9,5 7,0 - 8,5 2 (P1 & P2).Alkalinity (as CaCO3) ppm - - 3 Total. Alkalinity (as CaCO3) ppm 1000 max - 4 Total. Hardness (as CaCO3) ppm 800 max - 5 Calcium. Hardness (as CaCO3) ppm < 800 - 6 Chloride (as Cl) ppm 1000 Max - 7 Chlorine (as Cl2) ppm 0,2 - 0,5 - 8 Silica (as SiO2) ppm 150 max - 9 Iron (as Fe) ppm < 1,0 - 10 TDS ppm 1000 max - 11 Conductivity µhos 2000 max - 12 Concentration Factor 3 - 5 - 13 Warna Air (Visual) Clear - 14 Langelier Saturation Index(LSI)* -3 s/d +3 - *digunakan untuk dosis chemical liquid Keterangan 1. pH : Menunjukkan kadar asam atau basa dalam suatu larutan, melalui konsentrasi ion hidrogen H+, parameter yang menunjukkan kecenderungan terjadinya korosi dan pembentukan kerak. Controling dengan menggunakan Acid (menurunkan pH) & Caostic (menaikkan pH). 2. T-alkalinity : Dianalisa untuk memprediksi pertumbuhan kerak kalsium karbonat. M-alkalinity memiliki korelasi yang positif dengan pH. 3. Calcium hardness :...


Similar Free PDFs