MAN Truck Fault Codes ON- Board Computer (ZBR) PDF

Title MAN Truck Fault Codes ON- Board Computer (ZBR)
Author trucktec ahmed
Course Connaissance du métier
Institution Université Paris Nanterre
Pages 8
File Size 174.5 KB
File Type PDF
Total Downloads 35
Total Views 120

Summary

Revue Mécanique...


Description

MAN TRUCK FAULT CODES ON-BOARD COMPUTER (ZBR) https://truck-manuals.jimdo.com/man-fault-codes/man-fault-codes-zbr/ Code (SPN) Description Reason, verification and system response. 00038 Reserve, the fuel level in the tank 2. Priority 5: Display during stop and while driving. Fault: 1. too high; 2. Too low; 3. Unacceptable; 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: R1 / 14. 00070 Signal "parking brake". Priority 2: The fault, which requires removal of the service center. Fault: 8. Wrong signal. 00096 Reserve, the fuel level in the tank 1. Priority 5: Display during stop and while driving. Fault: 1. too high; 2. Too low; 3. Unacceptable; 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: R1 / 13. 00098 Engine oil level. 00100 Signal "Engine oil pressure." Priority 4: No display does not affect the operability. Fault: 8. Wrong signal. 00102 Signal "pressure air charge." A warning light on the instrument panel constantly lit in red, and when moving or stopped. Instead, the real pressure signal is simulated by a replacement signal. The engine is an inadequate amount of air, in consequence, significantly reduced power. Faulty sensor, broken wire, loose contacts, intercooler (intercooler) is blocked or forced air system is not tight. 00110 Signal "Engine coolant temperature". Priority 4: No display does not affect the operability. Fault: 8. Wrong signal. 00111 Signal "Engine coolant level". Priority 5: Display during stop and while driving. Fault: 6. Short to Ubat .; 10. Open. Pinout A302: R1 / 13. 00158 ZBR2 voltage power when the ignition (terminal 15, ignition). Priority 2: The fault, which requires removal of the service center. Pinout A302: ZE17. 00159 margin, the level of the gas pressure in the tank. Priority 2: The fault, which requires removal of the service center. Fault: 1. too high; 2. Too low; 5. Short to Ground; 6. Short to Ubat. Pinout A302: X / 1. 00168 ZBR2 voltage supply, plus a constant battery missing (terminal 30-0 Ubat.). Priority 1: Requires stopping the engine. Fault: 1. too high; 2. Too low; 10. Open. Pinout A302: ZE / 18. 00171 The temperature of the outside air. 00175 The oil temperature in the engine. 00190 engine speeds. A warning light on the instrument panel constantly lit in red, and when moving or stopped. The engine can not be started or the engine may stall spontaneously. Registration and collection of data on the signal of cranked and distributive shaft motor rotation speed is not functioning. 00513 Engine torque. 00520 Signal "The weakening of the braking retarder". Priority 4: No display does not affect the operability. Fault: 8. Wrong signal. 00597 Signal "Brake ABS, ASR, EBS" Priority 2: Fault requiring removal of the service center. Fault: 8. Wrong signal. 00 639 Data Bus T-CAN Higt, serial communication. Priority 1: Requires stopping the engine. Fault: 4. No signal. Pinout A302 M / 1. 00 639 Data Bus T-CAN Low, serial communication. Priority 1: Requires stopping the engine. Fault: 4. No signal. Pinout A302 M / 7. Including the transfer of 00 767 R. Priority 2: Fault requiring removal of the service center. Fault: 5. Short to Ground. Pinout A302 M / 6. 01007 Brake function replacement. 01031 function replacement parking lighting. 01086 residual pressure in the circuit 3 electric pneumatic system (ECAM). Priority 1: Requires the engine stop or Priority 2: Fault requiring removal of the service center. Fault: 1. too high; 2. Too low; 4. The signal is absent; 6. Short to Ubat. Pinout A302: R1 / 8. 01087 residual pressure in the circuit 1 electric pneumatic system (ECAM). Priority 1: Requires stopping the engine. Fault: 1. too high; 2. Too low; 4. The signal is absent; 6. Short to Ubat. Pinout A302: R1 / 11. 01088 2 residual pressure in the circuit of electric pneumatic system (ECAM). Priority 1: Requires stopping the engine. Fault: 1. too high; 2. Too low; 4. The signal is absent; 6. Short to Ubat. Pinout A302: R1 / 9. 01089 residual pressure in the electric circuit 4 of the pneumatic system (ECAM). Priority 1: Requires stopping the engine. Fault: 1. too high; 2. Too low; 4. The signal is absent; 6. Short to Ubat. Pinout A302 M / 2.

01235 data bus I-CAN Higt, serial communication. Priority 1: Requires stopping the engine. Fault: 4. No signal. Pinout A302: R2 / 9. 01235 data bus I-CAN Low, serial communication. Priority 1: Requires stopping the engine. Fault: 4. No signal. Pinout A302: R2 / 10. 01,376 ZBR2 voltage supply, plus a constant battery missing (terminal 30-1 Ubat.). Priority 1: Requires stopping the engine. Fault: 1. too high; 2. Too low; 10. Open. Pinout A302: ZE / 13. 01624 Vehicle speed. 01667 braking signal retarder (timeout). Priority 2: The fault, which requires removal of the service center. Fault: 8. Wrong signal. Chassis number 02987 in the tachograph or ZBR2 parameters do not fit to the car. Priority 1: Requires stopping the engine. Fault: 3. Unacceptable. 03000 ZBR2 system, information about emergency shutdown. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground. Pinout A302: F1 / 12. 03001 ZBR2 system, wake up the computer. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground. Pinout A302: F1 / 11. 03102 Terminal 30-1 is connected. Priority 1: Requires stopping the engine. Fault: 1. too high; 2. Too low; 10. Open. Pinout A302: ZE / 9. 03103 ZBR2 voltage supply, analog ground. Pinout A302 M / 16. 03104 ZBR2 voltage supply, analog ground. Pinout A302: R1 / 15. 03107 ZBR2 voltage supply, ignition switched on (relay terminal 15). Priority 2: The fault, which requires removal of the service center. Fault: 5. Short to Ground; 10. Open. Pinout A302: F2 / 12. 03,108 ZBR2 voltage supply batteries power switch. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 10. Open. Pinout A302: F2 / 18. 03111 ZBR2 voltage supply, starter switch (terminal 50). Priority 1: Requires stopping the engine. Priority 2: The fault, which requires removal of the service center. Priority 3: Display during stop. Priority 4: No display does not affect the operability. Priority 5: Display during stop and while driving. Pinout A302: ZE / 5. 03201 The pressure drop on the air filter of the engine. Priority 5: Display during stop and while driving. Fault: Too low 2; 5. Short to Ground; 6. Short to Ubat. Pinout A302: X / 3. 03300 Generator, W. Terminal Priority 2: Fault requiring removal of the service center. Fault: 3. Unacceptable. Pinout A302 M / 14. 03301 Generator, L. The terminal Priority 2: Fault requiring removal of the service center. Fault: 4. No signal. Pinout A302 M / 4. 03302 generator terminal B +. Priority 3: Display during stop. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302 M / 8. 03303 Signal D + (engine running). Priority 2: The fault, which requires removal of the service center. Fault: 5. Short to Ground; 6. Short to Ubat. Pinout A302: F2 / 17. 03 335 Supply voltage (no data). Priority 4: No display does not affect the operability. Fault: Fault 0 is missing or faulty control unit. 03400 Solenoid valve for preheating. Priority 3: Display during stop. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302 M / 13. 03401 Relay preheating. Priority 3: Display during stop. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: ZE / 8. 03402 Current glow plugs. Priority 3: Display during stop. Fault: 10. Open. Pinout A302: ZE / 19. 03403 Current glow plugs. Priority 3: Display during stop. Fault: Too low 2; 3. Unacceptable; 10. Open. Pinout A302: ZE / 20. 03500 Malfunction trailer ABS (ABS, ASR, EBS). Priority 5: Display during stop and while driving. Fault: Fault 0 is missing or faulty control unit. Pinout A302: X / 2. 03501 trailer ABS, power consumption. Priority 5: Display during stop and while driving. Fault: 1. too high; 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: R2 / 14. 03502 tractor braking signal. Priority 2: The fault, which requires removal of the service center. Fault: 1. too high; 2. Too low; 5. Short to Ground; 6. Closing naUbat .; 10. Open. Pinout A302: R2 / 4. 03503 braking signal trailer. Priority 2: The fault, which requires removal of the service center. Fault: 1. too high; 2. Too low; 5. Short to Ground; 6. Closing naUbat .; 10. Open. Pinout A302: R2 / 5. 03 568 retarder is enabled. Fault: Fault 0 is missing or faulty control unit. 03,569 engine brake is turned on. Fault: Fault 0 is missing or faulty control unit. 03570 The service brakes are included. Fault: Fault 0 is missing or faulty control unit.

03600 The fluid level in the clutch. Priority 5: Display during stop and while driving. Fault: 6. Short to Ubat .; 10. Open. Pinout A302: R1 / 2. 03602 Relay reversing light. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: F2 / 13. 03603 Turning otopleniyaKongsberg system. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302 M / 18. 03625 Creep speed. Priority 2: The fault, which requires removal of the service center. Fault: 6. Short to Ubat. Pinout A302: X / 4. 03 800 front axle level (air podveskaECAS). Priority 5: Display during stop and while driving. Fault: Fault 0 is missing or faulty control unit; 4. The signal is absent; 5. Short circuit to ground. Pinout A302: R2 / 17. 03,903 The fuel temperature in the tank 1. Priority 5: Display during stop and while driving. Fault: 1. too high; 2. too low. Pinout A302: R1 / 10. 04000 switch headlights. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: F1 / 17. 04001 Dipped beam, left side. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: BL / 6. 04002 Dipped beam, right side. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: BR / 2. 04003 Left headlamp height adjustment. Priority 5: Display during stop and while driving. Fault: Fault 0 is missing or faulty control unit; 3. Unacceptable; 4. The signal is absent; 8. wrong signal; 9. Faulty component. Pinout A302: BL / 3. 04004 Right headlamp height adjustment. Priority 5: Display during stop and while driving. Fault: Fault 0 is missing or faulty control unit; 3. Unacceptable; 4. The signal is absent; 8. wrong signal; 9. Faulty component. Pinout A302: BR / 6. 04005 Turning on the tractor, left rear. Priority 5: Display during stop and while driving. Fault: 1. too high; 2. Too low; 5. Short to Ground; 6. Closing naUbat .; 10. Open. Pinout A302: R2 / 1. 04006 Turning on the tractor, right rear. Priority 5: Display during stop and while driving. Fault: 1. too high; 2. Too low; 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: R2 / 13. 04007 Turning on the towing vehicle, or the front left side. Priority 5: Display during stop and while driving. Fault: 1. too high; 2. Too low; 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: BL / 4. 04008 Turning on the tractor, right front or side. Priority 5: Display during stop and while driving. Pinout A302: BR / 3. 04009 switch turns the pointer, the Hall sensor (on the steering wheel to the left). Priority 5: Display during stop and while driving. Fault: 6. Short to Ubat .; Pinout A302: F1 / 3. 04010 switch turns the pointer, the Hall sensor (on the steering wheel to the right). Priority 5: Display during stop and while driving. Fault: 6. Short to Ubat .; Pinout A302: F1 / 6. 04011 Switch flashing light on the left. Priority 5: Display during stop and while driving. Fault: 6. Short to Ubat .; 10. Open. Pinout A302: F1 / 15. 04012 Switch flashing light on the right. Priority 5: Display during stop and while driving. Fault: 6. Short to Ubat .; 10. Open. Pinout A302: F1 / 16. 04013 Alarm, warning lamp. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: F2 / 16. 04014 Alarm, switch. Priority 2: The fault, which requires removal of the service center. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: F1 / 1. 04015 Turning on the trailer to the left. Priority 5: Display during stop and while driving. Fault: 1. too high; 2. Too low; 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: R2 / 3. 04016 Turning on the trailer, right. Priority 5: Display during stop and while driving. Fault: 1. too high; 2. Too low; 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: R2 / 2. 04017 Main beam, left side. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: BL / 5. 04018 Main beam, right side. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: BR / 1. 04019 Main beam, push button. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: F1 / 13. 04020 Intermittent headlights, push button. 04021 additional main beam, left side. Priority 5: Display during stop and while driving. Fault: 5. Short to

Ground; 6. Short to Ubat .; 10. Open. Pinout A302: BL / 1. 04022 additional high beam, right side. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: BR / 4. 04023 additional high beams on the roof of the relay. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: F2 / 14. 04024 Rear fog lights on the tractor. Priority 5: Display during stop and while driving. Fault: 1. too high; 2. Too low; 5. Short to Ground; 6. Short to Ubat .; Pinout A302: R2 / 16. 04 025 Rear fog lights on the trailer. Priority 5: Display during stop and while driving. Fault: 1. too high; 2. Too low; 5. Short to Ground; 6. Short to Ubat .; Pinout A302: R2 / 15. 04026 Fog lights, right side. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: BR / 5. 04027 Fog lights, left side. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: BL / 2. 04028 Control lamp fog lights, unlocking inclusion. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; Pinout A302: X / 12. 04029 Additional fog lamp relay. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: F2 / 18. 04030 Lanterns parking lights on the vehicle right side. Priority 5: Display during stop and while driving. Fault: Fault 0 is missing or faulty control unit; 1. Too high; 2. Too low; 10. Open. Pinout A302: ZE / 1. 04031 Lanterns parking lights on the vehicle left side. Priority 5: Display during stop and while driving. Fault: Fault 0 is missing or faulty control unit; 1. Too high; 2. Too low; 10. Open. Pinout A302: ZE / 7. 04032 Lanterns parking light, right side. Priority 5: Display during stop and while driving. Fault: 3. Unacceptable. Pinout A302: ZE / 10. 04033 Lanterns parking light, left side. Priority 5: Display during stop and while driving. Fault: 3. Unacceptable. Pinout A302: ZE / 14. 04034 Side marker lights, right side. Priority 5: Display during stop and while driving. Fault: 1. too high; 2. Too low; 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: R2 / 7. 04 035 Side marker lights, left side. Priority 5: Display during stop and while driving. Fault: 1. too high; 2. Too low; 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: R2 / 6. 04036 Lanterns trailer parking light, right side. Priority 5: Display during stop and while driving. Fault: Fault 0 is missing or faulty control unit; 1. Too high; 2. Too low; 10. Open. Pinout A302: ZE / 3. 04037 Lanterns trailer parking light, left side. Priority 5: Display during stop and while driving. Fault: Fault 0 is missing or faulty control unit; 1. Too high; 2. Too low; 10. Open. Pinout A302: ZE / 2. 04,038 parking light switch. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: ZE / 4. 04039 Switch parking light. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: F1 / 14. 04040 Winter mode switch. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: F2 / 18. 04,042 Check the lighting. Priority 6: An indication of the critical state of security. 0. The fault is missing or defective control unit. 04043 Checking lighting lock. Priority 4: No display does not affect the operability. Fault: Fault 0 is missing or faulty control unit. 04,044 Check lighting unlock. Priority 4: No display does not affect the operability. Fault: Fault 0 is missing or faulty control unit. 04 045 System indicator lamps on both sides, including. Priority 5: Display during stop and while driving. Fault: 3. Unacceptable. 04046 calibration Identification of the headlamps angle system. Priority 4: No display does not affect the operability. Fault: Fault 0 is missing or faulty control unit. 04100 Middle winter light, right side. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: BR / 2. 04101 Middle winter light, left side. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: BL / 6. 04102 Far winter light, right side. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: BR / 1. 04103 Far winter light, left side. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground;

6. Short to Ubat .; 10. Open. Pinout A302: BL / 5. 04104 Lanterns back winter parking light, right side. Priority 5: Display during stop and while driving. Fault: Fault 0 is missing or faulty control unit; 1. Too high; 2. Too low; 10. Open. Pinout A302: ZE / 1. 04105 Tail light winter parking light, left side. Priority 5: Display during stop and while driving. Fault: Fault 0 is missing or faulty control unit; 1. Too high; 2. Too low; 10. Open. Pinout A302: ZE / 7. 04109 Switch camouflage headlight. Priority 5: Display during stop and while driving. Pinout A302: F1 / 2. 04113 Side light, right side, the relay. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: X / 17. 04200 interior lighting and lighting steps, right side. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: F2 / 5. 04201 interior lighting and lighting steps, left side. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: F2 / 4. 04300 windshield washer fluid, the level sensor. Priority 5: Display during stop and while driving. Fault: Too low 2; 6. Short to Ubat. Pinout A302: F1 / 7. 04301 windshield washer fluid pump. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: F2 / 15. 04302 wiper, intermittent switch. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; Pinout A302: F1 / 5. 04303 Wiper, master oscillator switches intermittent mode. Priority 2: The fault, which requires removal of the service center. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: X / 18. 04304 Washer, key switch. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; Pinout A302: F1 / 4. 04,305 wiper, rain sensor signal presence. Priority 3: Display during stop. Pinout A302: F1 / 18. 04306 Windscreen washers, liquid level sensor. Priority 5: Display during stop and while driving. Fault: Too low 2; 6. Short to Ubat .; 10. Open. Pinout A302: R1 / 5. 04307 Windscreen washers, pump. Priority 5: Display during stop and while driving. Fault: 5. Short to Ground; 6. Short to Ubat .; 10. Open. Pinout A302: F2 / 1. 04308 Wiper Motor, speed. Priority 2: The fault, which requires removal of the service center. Pinout A...


Similar Free PDFs