SEPLOS 48V 100A Battery Management System Specifications

SEPLOS 48V 100A BMS User Manual

Shenzhen Seplos Technology Co.,Ltd

www.seplos.com

SEPLOS 48V 100A Battery Management System Specifications

www.seplos.com

CONTENT

Shenzhen Seplos Technology Co.,Ltd.................................................................. 1 CONTENT.................................................................................................................... 2 1. Application............................................................................................................. 1 2. Electric Features.................................................................................................... 1 3. Diagram................................................................................................................... 3 4. Electric Features.................................................................................................... 4 5. Basic Parameters................................................................................................... 4 6. Indicator................................................................................................................ 15 7. Function Description......................................................................................... 18 8. Working Mode.................................................................................................... 22 9. Dimension............................................................................................................ 23 10. Interface.............................................................................................................. 24 11. Communication................................................................................................ 24 12. LCD Screen......................................................................................................... 27 13. Precautions........................................................................................................ 28

2

SEPLOS 48V 100A Battery Management System Specifications

www.seplos.com

1. Application This Battery Management System(BMS) is designed to monitor 8-16 cells in series battery pack. It has multiple functions, including single cell over voltage and under voltage protection, pack over voltage and under voltage protection, charging and discharging over current protection, high and low temperature protection, short circuit protection and protection recovery. what’s more, it can also calculate the SOC status precisely and keep voltage balancing during charging and discharging, and collect the SOH statistics. All monitoring parameter settings and data can be configurable through the communication between RS485 and the master via CAN BUS and communicating with software on PCs. (Master controller baud rate 9600.)

2. Electric Features 2.1 cell and pack voltage monitoring The BMS measure the voltage difference in real-time. And provide over voltage and under voltage warnings once the the the cell voltages are out of safe operating voltage range. At room temperature of 0-45 ℃ , the measured voltage difference is about ±10mV. However, at the temperature of -20~0℃ and 45~70℃, the measured voltage difference is up to ±30mV. 2.2 Temperature of individual cell, environment Temperature and power temperature monitoring The BMS measure the cell temperature, ambient temperature and power temperature in real-time via NTC to provide high temperature or low temperature warnings and protections. The measured temperature difference is within ±2℃. 2.3 Charging and discharging current monitoring The BMS calculate the in or out loading current by monitoring the impedance in the charging and discharging circuit. And providing over current or short circuit warnings and protections. If the operating temperature is lower than 40 ℃ , the measured current count is within 1% difference. 2.4 Short-circuit Protection Function

1

SEPLOS 48V 100A Battery Management System Specifications

www.seplos.com

The BMS monitors the output circuit and provides short circuit protection. 2.5 Capacity and cycle life The BMS estimate the remaining capacity of the battery pack after the primary full charge and discharge. The capacity count is within in 5% difference. And for the cycle life, it can calculate the cycle life according to your setting DOD percentage. 2.6 Charging and discharging MOSFET power switch monitoring The MOSFET power switch, featuring low internal resistance, big current, is an optimization design for the capacitive load starting, switch free, fast charging and high voltage of back up battery bank. 2.7 Individual cell equalization Settings of charging and standby can be configurable to prolong the battery pack cycle life. 2.8 LED indicator 6 LED lights indicate the battery remaining capacity, operating mode and warning status. 2.9 Power switch The power switch is used to power on/off the battery manually. 2.10 CAN and RS485 communication interface The data monitoring, battery pack control and parameter settings can be remote controlled through software on PCs or mobile devices. 2.11 Battery management parameter settings All the parameter settings, including individual cell over voltage, battery pack over voltage, over current during charging and discharging, high temperature of battery cell and operating environment, equalizing strategy, battery pack in series, battery capacity etc., can be reset through battery studio software. 2.12 Battery management function settings All voltage, temperature, current and capacity related functions can be turned on/off manually with host-application battery studio software. 2.13 Soft start and charging current limitation 2

SEPLOS 48V 100A Battery Management System Specifications

www.seplos.com

Start time can be set from 1ms-1000ms to apply to different capacitive load. Limited charge current can be turned on or off. Turn on the limited charge current function can prevent parallel circulation and impact from the charger. 2.14 Parallel Communication The address can be set through RS485 concatenation and 8 dial addresses. The terminal device can read the battery data of the PACK parallel machine through the CAN interface. 2.15 historical data record Historical data is stored according to the state transition of the BMS; real-time storage of measurement data when various alarms, protection triggers and eliminations; realizing the storage of measurement data within a certain period of time by setting the recording start time, recording end time and recording interval . Currently, it can store up to 300 historical data records, which can be read by the host computer and saved as an excel file to the computer.

3. Diagram

3

SEPLOS 48V 100A Battery Management System Specifications

www.seplos.com

4. Electric Features

Item

Min

Max.

Type

Operating Temperature(V)

20V

30V

24V

Standard Charge Voltage(V)

25V

31V

28V

Operating Temperature Range(℃)

-20℃

70℃

28℃

Continuously Charging Current(A)

100A

Continuously Discharging Current(A)

100A

Discharge Output Impedance(mΩ)

1A.

condition Over voltage warning Pack over voltage

57.0V

configurable

56.4V

configurable

44.8V

configurable

48V

configurable

58.4V

configurable

55V

configurable

threshold OFF

warning

Over voltage recovery warning threshold Under voltage warning threshold

Pack under voltage ON warning

Under voltage recovery warning threshold Over voltage protection threshold

Pack over voltage OFF protection

Over voltage protection recovery threshold

6

SEPLOS 48V 100A Battery Management System Specifications

www.seplos.com

1. Cell voltage count decreases to the recovery threshold. Over voltage protection 2. Discharge current should be>1A. recovery conditions 3. The remaining capacity lower than intermittent capacity compensation.

Under voltage 41.6V

configurable

46V

configurable

protection threshold Under voltage protection recovery threshold Pack under voltage ON protection

Turn off the system and maintain Auto power off at low communication for 10s after the reaching under temperature voltage protection limitation. Under voltage Charge current should be>1A.

protection recovery condition High temperature

50℃

35℃-80℃

47℃

35℃-80℃

warning threshold Charge Temperature

ON

High temperature warning recovery threshold

7

SEPLOS 48V 100A Battery Management System Specifications

www.seplos.com

Limit high temperature 60℃

35℃-80℃

50℃

35℃-80℃

2℃

-20℃-10℃

5℃

-20℃-10℃

-10℃

-20℃-10℃

0℃

-20℃-10℃

52℃

35℃-80℃

47℃

35℃-80℃

warning threshold Limit high temperature warning recovery Charge Temperature

ON

threshold Low temperature warning threshold Low temperature warning recovery threshold Limit low temperature protection threshold Limit low temperature protection recovery threshold High temperature warning threshold

Discharge Temperature

ON

High Temperature warning recovery threshold

8

SEPLOS 48V 100A Battery Management System Specifications

www.seplos.com

Limit high temperature 60℃

35℃-80℃

50℃

35℃-80℃

-10℃

-20℃-10℃

3℃

-20℃-10℃

-10℃

-20℃-10℃

-10℃

-20℃-10℃

50℃

-20℃-60℃

47℃

-20℃-80℃

warning threshold Limit high temperature warning recovery threshold Low temperature warning threshold Discharge Temperature

Low temperature ON

warning recovery threshold Limit low temperature protection threshold Limit low temperature protection recovery threshold High air temperature

Environment Temperature Warnings

warning threshold ON

High air temperature warning recovery threshold

9

SEPLOS 48V 100A Battery Management System Specifications

www.seplos.com

Low air temperature -10℃

-20℃-60℃

3℃

-20℃-60℃

80℃

60℃-120℃

75℃

60℃-120℃

100℃

60℃-120℃

85℃

60℃-120℃

warning threshold Low air temperature warning recovery threshold High power temperature warning threshold High power temperature warning recovery threshold

Power Temperature ON Warnings

Limit high power temperature warning recovery threshold Limit high power temperature warning recovery threshold Over current warning

0A-charging protecting 50A

Charging Over

threshold

current threshold

Over current warning

0A-charging warning

ON Current Warning

45A recovery threshold

current threshold

10

SEPLOS 48V 100A Battery Management System Specifications

www.seplos.com

Over current protection 160A

0A-150A

threshold Charging Over

Charge over current ON

Current Protection

10S time delay threshold Over current protection 1. automatically recover 60s later. recovery conditions

2. once the battery begins to discharge. 10A (0A indicates the

Charge Current

Limit charge current

termination of

ON Limitation

0A-10A threshold

current limitation function)

Effective Charge Current

Current in during charge

600mA

Current out during charge

500mA

Discharge over current

0A-discharging protecting -105A

warning threshold

current threshold

Discharging Over ON

Discharge over current 0A-discharging warning

Current Warning warning recovery

-103A current threshold

threshold Discharge over current

0A- 2nd discharge -110A

Discharging Over

protecting threshold

protecting current

ON Current Protection

Discharge over current 10S time delay threshold

11

1S-600S

SEPLOS 48V 100A Battery Management System Specifications

www.seplos.com

2nd over current

Discharge protecting -200A

protection threshold

current threshold-300A

2nd Discharge over current time delay

100mS

1mS-500mS

ON threshold 2nd over current 1. automatically recover 60s later. protection recovery

2nd Over Current

2. once the battery begins to charge. threshold

Protection

over current for 2 times, or the lock times over 2nd over current lock the threshold Over current protection OFF

5 times lock times unlock 2nd over current Connected to a charger protection lock Short circuit protection Continuously short, or the short circuit lock

Short Circuit

protection lock times over threshold

Short circuit protection ON

Protection (output)

5 times lock times Unlock Short circuit connected to a charger protection lock

Effective Discharge

Current in during discharge

12

-1000mA

SEPLOS 48V 100A Battery Management System Specifications

Current

www.seplos.com

Current out during discharge Charge equalizing

-900mA At charging or float charging status

equalizing voltage 3350mV ON

threshold Equalizing voltage 30mV difference

Equalizing Function

Equalizing temperature Automatically start according to the limitation

environment temperature

High temperature ON

50℃ threshold Low temperature 0℃ threshold Voltage difference of cell failure warning

500mV

threshold Cell Failure Warning

ON Voltage difference of cell failure warning

300mV

recovery threshold Rated Capacity

100Ah

5-200Ah

Capacity Remaining Capacity

Calculate accordingly to the cell voltage

13

SEPLOS 48V 100A Battery Management System Specifications

www.seplos.com

Remaining Capacity ON

15% warning threshold When the BMS at the dormant state, activate the

POWER ON/ACTIVATE

BMS by pressing this button. Then, the LED lights are on. The system enters into working mode.

Button When the BMS at standby or operating status, hold the button for 3s. Then, the LED lights were

POWER OFF/STANDBY

on. The system enters dormant state. BMS power 48h (no effective discharge current and no consumption

Longest standby time charge connected)

management Precharging

1000-5000ms

Pre-charge function starts at the moment of

options

BMS is on.

3000ms Function

Cell low temperature 0℃ heating Heating Function (At

threshold OFF

Low Temperature )

Configurable Cell low temperature 10℃ heating recovery threshold

14

SEPLOS 48V 100A Battery Management System Specifications

www.seplos.com

BMS can be turned on and off by operating external switch in Internal Switch

ON standby mode. Simplified monitoring software, you can view data such as cell,

LCD Screen

ON temperature, current, etc. Impedance compensation of

Default value between

Compensation

8-9mΩ

impedance

10mΩ

connection fault Impedance

Battery connection compensation

Compensation

0mΩ

impedance

9

impedance compensation compensation 0mΩ

13

Configurable

impedance

6. Indicator

6.1 Capacity indicator Status

Charge

Discharge

Capacity ●L4

●L3

●L2

●L1

●L4

●L3

●L2

●L1

indicator Solid 0-25%

OFF

OFF

OFF

Blink

OFF

OFF

OFF Green

15

SEPLOS 48V 100A Battery Management System Specifications

www.seplos.com

Solid 25%-50%

OFF

OFF

Blink

Solid

Solid

Green

Green

Solid

Solid

Solid

Green

Green

Green

OFF

OFF

Green Solid 50%-75%

OFF

>75%

Solid

Blink

OFF Green

Green

Solid

Solid

Solid

Solid

Solid

Solid

Solid

Green

Green

Green

Green

Green

Green

Green

Blink

Operating Solid Green

Blink

indicator

6.2 Light Blink explanation Blink Mode

ON

OFF

Blink once

0.25s

3.75s

Blink twice

0.5s

0.5s

Blink Three times

0.5s

1.5s

6.3 Status indicator Operating

Operating

status

Mode

Power off Standby

RUN

ALM

LED Light Remark













Standby

OFF

OFF

OFF

OFF

OFF

OFF

Normal

Blink green

OFF

OFF

16

OFF Standby

SEPLOS 48V 100A Battery Management System Specifications

www.seplos.com

once Blink green

Blink Red

once

Once

OFF

Solid Red

Solid Green

OFF

Warning

Low voltage

Discharge protection Normal

Blink Red Warning

Solid Green

Float Charge

Solid Green according to battery Once power level

Charge Solid Green

Solid Red

Solid Green

OFF

protection Normal
<...


Similar Free PDFs